| Product Name: Permanent magnet synchronous motor drive V8-H | | | Price: | | manufacturer: | | Add Time: 2013/5/2 17:10:49 | |  | | | The V8 series products are high performance vector control / torque control of core technology platform for driving synchronous motor drive based on, suitable for injection molding machine, oil machine, machine tool, electric cars, hybrid cars and other industries synchronous motor drive. ◆ vector control 1: Both vector control performance is not sensitive to the motor parameter. Starting torque Rated torque: 0.50Hz 180% Speed range: 1:100 Steady speed precision: + 0.5% 0.50Hz can control the motor to run 150% of rated torque. ◆ without encoder speed feedback vector control 2: Accurate without speed really realize AC motor decoupling technology sensor vector control, the control of DC motor. Starting torque Rated torque: 0.25Hz 180% Speed range: 1:200 Steady speed precision: + 0.2% 0.25Hz can control the motor to run 150% of rated torque. ◆ with encoder speed feedback vector control 2: Starting torque Rated torque: 0.00Hz 180% Speed range: 1:1000 Steady speed precision: + 0.02% Open the ring torque control mode: Current loop independent control to realize the real torque control, torque and speed control switch support. Torque accuracy: + 5% The torque response: <20ms ◆ closed-loop torque control mode: Current loop independent control to realize the real torque control, torque and speed control switch support. Torque accuracy: + 5% The torque response: <10ms Power (kW) 0.75 1.5 2.2 3.7 5.5 7.51115 18.5223037455575 Matching motor power (kW) 0.75 1.5 2.2 3.7 5.5 7.51115 18.5223037455575 The output voltage (V) from 0 to 3 of the rated input voltage Rated current (A) 2.5 3.8 5.59131724303945 607591112150 Overload capacity of 1 minutes 10 seconds 150%, 180%, 200% and 0.5 seconds, 10 minutes apart (inverse time characteristic) Input rated voltage / frequency 3 380V ~ 480V; 50Hz/60Hz Allowable voltage range of 323V to 528V; voltage unbalance: ≤ 3%; allow the frequency fluctuation: + 5% Rated current (A) 3.5 6.2 9.2 14.9 21.5 27.939 50.360698610412415 201 The braking unit standard built-in optional built-in Protection class IP20 Since the cold forced air-cooled cooling mode Technical indicators Control the characteristic control vector control (no encoder) vector control two (with encoder) The starting torque of 0.50Hz 180% 0.00Hz 180% The speed range is 1:100 1:1000 Steady speed precision ± 0.5% ± 0.02% Torque control without Torque accuracy ± 5% The torque response time - <10ms Product function key function under pressure regulation, three switch, speed tracking, torque limit, multi-speed operation (up to 23), self-tuning, S curve acceleration and deceleration, slip compensation, PID regulation, droop control, current control, torque / speed control mode switch, manual / automatic torque lifting, current limit, multifunction input / output terminals Frequency setting mode operation panel set, terminal UP/DN setting, communication setting, simulation setup AI1/AI2/AI3, pulse DI set The frequency range of 0 ~ 300.00Hz Start frequency 0 ~ 60.00Hz Acceleration and deceleration time of 0.1 ~ 36000s Energy consumption braking braking unit operating voltage: 650 ~ 750V DC braking capacity of the DC brake initial frequency: 0 ~ 300.00Hz; DC braking current: 0 ~ 120% DC brake time: 0 ~ 30.0S; without DC braking initial waiting time, fast brake Magnetic brake function has been action, deceleration without action is optional, the factory default reduction without action The multifunction key features of multifunctional M key original set frequently used operations: JOG, emergency stop, run the command given mode switching, menu etc. Multiple menu mode menu mode, quick menu mode, non factory value function code menu mode, the function code 10 menu mode, the recent changes * Parameter copy standard operating panel can realize parameter upload, download, copy of the progress indicator; the parameters have been uploaded can disable upload cover Function code explicit and tacit customer can customize any function code group show, hide Double 485 port double 485 communication interface supports the Modbus protocol (RTU), standard operation panel can realize remote control box, the distance of 500 meters Operation panel optional button or shuttle operation panel, protection grade standard products for the IP20, protection grade IP54 optional Common DC bus series can realize multiple inverters of common DC bus power supply The series uses independence independent air duct design, install radiator support outside the cabinet Universal extension of universal expansion board connector support customer to develop two times with CPU: physical interface of SPI bus, software protocol Modbus The expansion card user two times the development of card, plastic card, PG card, air compressor control card, communication adapter, power monitoring card, phase sequence detection card, external power supply rectifier card etc. Power on self realization of internal and external circuit power-on self test, such as electrical grounding, +10V power supply, analog input, output abnormal abnormal disconnection The protection function of power undervoltage, overcurrent protection, overvoltage protection, interference protection, baseline abnormalities, self-tuning module protection, fault, radiator overheated protection, overload protection, motor overload protection, peripheral protection, current anomaly detection, output short circuit to ground operation in abnormal, abnormal power down input, output, power supply is abnormal phase anomaly, EEPROM anomaly, relay, temperature sampling, abnormal disconnection encoder disconnected, +10V power output, analog input, abnormal abnormal motor overheating (PTC), communication is abnormal, abnormal, abnormal, copy version compatible expansion card connection exception, terminal mutex check failed, hardware overload protection Efficiency rating, 7.5kW and below power level ≥ 93%; 45kW and below the power level ≥ 95%; 55kW and above power level ≥ 98% The environment used in well ventilated place vertically installed within the cabinet. Do not allow the level or other installation. The cooling medium is air. Installed in the not subject to direct sunlight, no dust, no corrosive gas, no flammable gas, no oil mist, no steam, no drop of water environment Ambient temperature - 10 ℃ to +40 ℃, between 40 ~ 50 ℃ derating, every increase of 1 degrees, the rated output current is reduced by 1% Humidity from 5 to 95%, do not allow the gel Altitude 0 ~ 2000 meters, 1000 meters above the derating, every increase of 100 meters, rated output current is reduced to 1% Shake 3.5mm, 2 ~ 9Hz; 10 m/s2, 9 ~ 200Hz; 15 m/s2200 ~ 500Hz Storage temperature − 40 ~ +70 ℃ | | | Clicks: 5271 |  |
|
|